• Sourcing Solutions
  • Services & Membership
  • Help & Community

Quick Details

  • Place of Origin: Henan, China (Mainland)
  • Brand Name: KAIDE
  • Model Number: KDLD
  • Accuracy: +/-0.5%, +/-0.2%(customize)
  • Signal output: Pulse, 4-20mA standard current output
  • Power supply: 16~36V DC, 85~250V AC
  • Flange pressure: 40bar,25bar,20bar,16bar,10bar,6bar
  • Liner: PTFE,Rubber,Hard Rubber,FEP,PFA,etc
  • Electrode: SS316,HB,HC,Ti,Ta,etc.
  • communication: RS485, Modlbus, RS232, HART, etc.
  • Explosion-proof: Exdmb II CT6
  • Protection grade: IP67/IP68(under water)
  • Product: Milk flowmeter

Packaging & Delivery

Packaging Details Milk flowmeter:
Foreign trade standard packing for electromagnetic flow meter, wooden cases with foaming agent inside.
DN80:
Compact type size:350*350*550(mm), gross weight: 25Kg
Remote type size:350*350*550(mm), gross weight: 25Kg
Others, for example:
DN150:
Compact type size:340*330*600(mm), gross weight: 35Kg
Remote type size:450*340*600(mm), gross weight: 38Kg
DN65:
Compact type size:300*350*480(mm), gross weight: 20Kg
Remote type size:320*350*480(mm), gross weight: 20Kg
Delivery Time 7 days

Specifications

Milk flowmeter:
Communications: RS485, Modbus, HART, GPRS
Output: Pulse and 4-20mA
Protection: IP67, IP68 (underwater)

 

Product Description

Pulse and 4-20mA output low price electromagnetic milk flowmeter

 

Brief introduction- milk flowmeter 

Electromagnetic flow meter is a kind of induction type flow instrument often used to measure, based on Faraday Law, the volume flowrate of conductive medium in closed pipelines. With microprocessor and exclusive integrated circuit, KDLD electromagnetic flow meter have the advantages of reliable performance, high accuracy, easy to use, etc.. The high speed CPU and advanced signal processing technology ensure a wide measuring range of 0.01m/s to 12m/s. The infrared remote control realize man-machine conversation, two-line LCD makes the readings and parameter setting more comprehensive and convenient.

 

KDLD electromagnetic flow meter can be widely applied in industries like chemical, power supply, metallurgical mine, oil, water supply and drainage, paper making, pharmaceutical, food, etc..

 

Characteristics- milk flowmeter 

 

1. Variable forms for different kinds of working conditions. Compact and remote form; Flanged, flange wafer, clamped, threaded, insertion end connection; DC/AC, battery power supply.

 

2. High accuracy of ±0.5%.

 

3. Wide size range of 10mm~3000mm, adapt to different size of pipelines.

 

4. Full choice of liner to accommodate conductive medium from drinking water to strongly corrosive liquid like sulfuric acid.

 

5. Measurement is not affected by the density, viscosity, temperature, pressure and electroconductibility of fluid.

 

6. Two-line LCD, able to display positive and negative instantaneous flow and accumulative flow.

 

7. No pressure loss. No moving parts.

 

8. Pulse and 4~20mA standard current output. Multiple choice of communications: RS232, RS485, Modbus, Profibus, HART, etc..

 

9. Surface mount technology(SMT) technology of converter which possesses self-check and self-diagnose functions.

 

10. Explosion-proof type can be used at relevant explosion-proof sites. IP68 remote type can be used underwater.

 

 

Product Classification- milk flowmeter 

 

Electromagnetic flow meter is composed of sensor and converter. Therefore it can be classified as compact type and remote type. For remote type, the sensor and converter is connected by cable.

 

Based on the power supply mode, DC/AC and battery powered type.    

                      

Based on end connection difference, we have flanged connection, Flange wafer connection, Clamped connection, Threaded connection and Insertion type.

 

Features

Compact type

Remote type

Flange type

Flange wafer type

clamped type

Threaded type

Insertion type

AC/DC type

Battery powered

Model No.

KDLD-Y

KDLD-F

KDLD-Y/F

KDLD-KZ

KDLD-JZ

KDLD-LW

KDLD-CR

KDLD-Y/F

KDLD-DC

Sensor type

F

F

F

K

J

L

C

F

F

DN size(mm)

10~3000

10~3000

10~3000

25~200

25~200

15~50

150~3000

10~3000

10~600

Measuring medium

Liquid or solid-liquid phase medium with a conductivity higher than 5μs/cm.

Measuring accuracy

±0.5%FS, ±2.5%FS for insertion type

Liner material

Polytetrafluoroethylene(PTFE), Fluorinated Ethylene-Propylene(FEP), Polychloroprene Rubber, Polyurethane, Hard Rubber, etc..

Electrode

Available forms: Fixed or blade form;

Available material: Stainless steel 316L, hastelloy B,hastelloy C,titanium alloy,tantalum alloy, platinum-iridium alloy,stainless steel-coated wolfram carbide, etc.

Sensor material

Measuring tube: stainless steel;   Housing and flange: carbon steel(SS available);   Wire: copper;   Wire housing: carbon steel  Junction box: Aluminium

PN Grade

DN15~DN150: 4.0MPa, DN15~DN600: 1.6 MPa, DN200~DN1000: 1.0MPa, DN700~DN3000: 0.6MPa. 16MPa, 25MPa, 32MPa available for special order.

Signal output

4~20mA standard current and pulse.

Display

Backlight LCD, able to display positive and negative instantaneous and accumulative flow. Instantaneous for battery powered type.

Conditions

Ambient: temperature -20~60, RH 5%~95%; Working temperature: -20~150

Flange standard

Chinese national standard GB, DIN, ANSI/ASME, JIS, etc..

Power supply

16~36V DC,  85~250V AC

3.6V

Communications

RS485, Modbus, RS232, GART, Profibus, GPRS, etc.

Explosion-proof

ExdmbⅡCT6

Protection Grade

IP65

IP67 / IP68

IP65(compact), IP67/IP68(remote)

IP 6

Table1.  Specification comparison table of all kinds of products

The electromagnetic flow meter and sensor- milk flowmeter

 

Peak flow rate

15m/s

Accuracy

(refer to accuracy curve)

Indication ±0.5%(flow rate no less than 0.8m/s)

Conductibility of fluid

Above 5μ S/cm

 

Nominal pressure

DN15~ DN150

4.0Mpa

DN15~DN600

1.6Mpa

DN200~DN1000

1.0Mpa

DN200~DN3000

0.6Mpa

Ambient temperature

Sensor

-25~+60 Deg C

Compact flow meter and converter

-10~+60 Deg C

 

 

 

The liner material and maximum temperature of fluid

Liner material

Remote type

Compact type

Polytetrafluoroethylene

(PTFE)

100°C(standard)

150°C(special order)

70°C

Polyvinyl fluoride

(PVF)

100°C(standard)

150°C(special order)

70°C

Fluorinated

ethylene-propylene(FEP)

100°C(standard)

150°C(special order)

70°C

Polychloropree rubber(CR)

80°C(standard)

120°C(special order)

70°C

Polyurethane(PU)

80°C

70°C

Electrode type

Fixed type(DN150~DN2600); Blade type(DN300~DN1600)

Material of signal electrode and grounding electrode

Mo-containing stainless steel, hastelloy B, hastelloy C, tantalum alloy, titanium alloy, platinum-iridium alloy, stainless steel-coated wolfram carbide

Flange material

Carbon steel

Grounding flange material

Stainless steel 1Cr18Ni9Ti

Seal ring material

PTFE

Material of inlet protection flange

DN6~DN600

Stainless steel 1Cr18Ni9Ti

DN700~DN3000

Carbon steel

Shell protection

DN6~DN150 remote sensor with rubber or polyurethane liner

IP65(standard),

IP68(special order)

DN200~DN3000 remote sensor with rubber or polyurethane liner

IP68(able to 5~10m under water usage)

Other sensor and all kinds of converter

IP65

Power supply

24VDC/220VAC

Signal output

Pulse, 4-20mA

Communication

RS485, Modbus(standard),

RS232,HART,Profibus, GPRS(special order)

Display

Digital 2-line LCD, able to display positive and negative instantaneous flow and accumulative flow

Spacing (remote type)

Generally, the spacing between converter and sensor is no longer than 100 meters, special order will be required when it is longer than 100 meters.

Table2 The electromagnetic flow meter and sensor

 

Convertors- milk flowmeter

 

L-mag B Convertor- milk flowmeter

With high speed CPU and advanced signal processing technology, L-mag B series convertor is able to provide stable and accurate performance. Deployed with which, the measuring accuracy of KDLD electromagnetic flow meter can be ensured better than ±0.5% in the flow rate range of 0.1~10m/s.

 

Display: Three-line LCD, have three integrator inside, positive accumulative flow, negative accumulative flow, and the difference total of the two.

 

Parameters setting: The parameters, such as flow unit, instrument factor, pulse equivalent, signal output range, etc., can be set through the buttons on the remote control or panel.

 

Current output: 4~20mA; 0~10mA.

 

Digital frequency and pulse output:

 

Alarm output: High alarm, low alarm,etc.

 

Power supply: 16~36V DC / 85~250V AC.

 

Communication interface: RS485, RS232

 

Communications: HART, Modebus, Profibus

 

Protection grade: IP65

 

KDLD Battery Powered Converter- milk flowmeter

 

It is designed for electromagnetic flow meters that are used in the open field, the 3.6V battery has a service life of more than 5 years. With SRD, GPRS and CDMA remote signal transmission, you can get the info without being on site. Applicable size: DN10~600

 

Selection of Nominal Diameter- milk flowmeter

1.As electromagnetic flowmeter has a high rangeability of 1500:1, the selection of nominal diameter is the same as that of process pipe;

 

2.If there are solid particle in the measured medium, a flow rate range of 1~3m/s is recommended. If the practical flow rate is excessive yet inconvenient to adjust, the nominal diameter of the instrument is better larger than that of the process pipe, under which condition the flow rate in the measuring pipe of the flowmeter can be properly decreased and the abrasion of electrode and liner caused by the particle can be alleviated;

 

3.If there are sediment in the process pipe, a flow rate range of 1~3m/s is recommended. If the practical flow rate is too little, the nominal diameter of the instrument is better smaller than that of the process pipe in order to properly increase the flow rate of the fluid in the flowmeter to avoid the effect on the accuracy caused by the sediment.

 

4.If the flow rate is too little yet a high-precision measurement is required, a sensor smaller than the nominal diameter can increase the flow rate to ensure high precision.

 

In the above 2,3,4 conditions, a reducing pipe should be jointed to both the upstream and downstream of the flowmeter. The center taper angle should be no more than 150 and there should be a straight pipe at least 5 times of the the process pipe jointed to the reducing pipe.

 

To help making lectotype, several flow values which corresponding to the certain typical flow rate are listed in the table below, any flow value could be quickly work out based on the corresponding flow rate: If a flow value is known as Q(m3/h), according to the relevant nominal diameter, check out the corresponding flow value Qwith a flow rate of 1m/s, then the flow rate can be work out through a formula as V=Q/Q1(m/s).

 

 

 

Table3.Comparison table of flow and flowrate

 

Packaging & Shipping

Packaging- milk flowmeter

 

Foreign trade standard packing for electromagnetic flow meter, foaming agent filling inside.

 

 

Our Services

 

 We Promise- milk flowmeter

 

1.We send the same quantity products free or send payment back once customers find problem when get goods.

 

 2.We will reply you within a workday and come up with solutions within 5 workdays when we receive your claim.

 

 3.We will reply you within a workday when receive your inquiry.

 

Company Information

Company Profile- milk flowmeter

 

We have been in this business for more than ten years. 

 

Our customer satisfaction is 99.5%.

 

We are located in Kaifeng, the most ancient and biggest base of flow instrument in China, which means we have full access to the most advanced technologies in this field.

 

We are awarded ISO9001:2008.

 

Our belief is "Accuracy and Attitude, Access to Customer".

 

Our monthly output of electromagnetic flow meters is 2000 pcs.

 

We are able to provide electromagnetic flow meters with international standards.

 

Our goal is to make world wide brand.


Part of the certifications- milk flowmeter

 

 

 

 

 

 

 

Transaction History of the Supplier

Below is the information about the supplier's transactions conducted via Alibaba.com. If you require further details regarding the transaction data, please contact the supplier directly.

Transaction Overview

Transactions

Transaction Details

This supplier has completedtransactions with buyers from .

Shipping Destination
Transaction Value
Transaction Date
Email to this supplier
China (Mainland) | Manufacturer
Transaction Level:
Supplier Assessments:
The supplier supports Trade Assurance – A free service that protects your orders from payment to delivery.
Supplier's Trade Assurance Limit: US $34,000
Learn More